Heat moves through a building three ways — conduction, convection, radiation — and the exam tests which mechanism applies and how the conductive-loss metrics (R-value, U-value) relate.
Key points
- Conduction: direct heat transfer through a material in contact (the heat path through walls, glass, and structure).
- Convection: heat carried by a moving fluid — air or water.
- Radiation: heat transferred by electromagnetic waves; needs no intervening medium (e.g. solar gain through a window, controlled by SHGC).
- The conduction chain of properties: conductivity k (rate heat passes through a material) → resistivity r is its inverse (1/k) → applied to a specific element these become conductance C and resistance R.
- R-value = resistance to conductive heat flow; add R-values in series through an assembly to get total R. Higher R = better insulator.
- U-value (transmittance) = overall rate an assembly conducts heat = 1 / total R. Lower U = better. Windows are rated by U-value (assembly heat loss) plus SHGC and VLT.
Confusions / comparison
| What it measures | Direction of “good” | Relationship | |
|---|---|---|---|
| Conductivity k | material property: heat-transfer rate per unit thickness | lower k = better insulator | r = 1/k |
| Resistivity r | material property: resistance to heat flow | higher r = better insulator | r = 1/k |
| R-value | a specific element/assembly’s resistance | higher R = better | R-values add in series |
| U-value | a specific assembly’s overall conductance (transmittance) | lower U = better | U = 1 / total R |
| Conduction | Convection | Radiation | |
|---|---|---|---|
| Carrier | material in contact | moving fluid (air/water) | electromagnetic waves |
| Needs a medium? | yes | yes | no |
| Building example | wall/window heat loss | air movement, hydronic loops | solar gain (SHGC) |
| Key metric | R-value / U-value | — | SHGC |
One window loses heat three ways at once
SchematicConduction crosses solids, convection circulates gas, and radiation crosses the glazing gap; total R and U are reciprocal.
View diagram Hide diagram
Scroll horizontally to explore
R-values of layers in series add. U-value is the reciprocal of total R—do not add U-values in the same way.