Building area types: GBA, Usable, Rentable, and Net Assignable Area

One-line orientation

These area terms draw different boundaries around the same floor. Learn where each boundary is measured and which shared spaces it includes.

Key points

  • Gross Building Area (GBA): Measured to the outside face of exterior walls. Includes everything inside: occupied spaces, circulation (primary + secondary), mechanical rooms, vertical penetrations (stairs, elevators, shafts), and service areas. The largest and most inclusive figure.
  • Usable Area: Measured to the inside face of exterior walls and the finish face of walls enclosing vertical penetrations. Includes net (assignable) area and secondary circulation. Excludes core areas shared by multiple tenants (building service core).
  • Rentable Area: Includes Usable Area plus service areas and primary circulation. Excludes vertical penetrations. Used for lease calculations; the exact extent may vary by lease terms.
  • Net Assignable Area (NAA): Measured to the inside faces of the walls enclosing each assignable space — wall thicknesses are not counted. In BRM’s programming model, Net Assignable Area (NAA) excludes general circulation and mechanical rooms. Other standards may treat service spaces differently. This is the space actually dedicated to programmatic functions — what the program document lists.
  • Where the terms come from: Usable and Rentable are office-leasing measurements standardized by ANSI/BOMA Z65.1; NAA (net assignable square feet) is the programming / institutional measure (FICM). BOMA measurements support leasing, while institutional programming standards define assignable program area. Do not combine their boundaries in one calculation.

Building area types: a conceptual boundary comparison

The nesting is a study model only; confirm one compatible measurement standard before calculating.

View diagram Hide diagram

Scroll horizontally to explore

Building area types as directly labelled nested boundaries Four equal-inset rectangular boundaries compare Gross Building Area, Rentable Area, Usable Area, and Net Assignable Area as a conceptual study hierarchy. GBA (gross building area) is measured to the outside face of exterior walls and includes all areas. Rentable and Usable are BOMA leasing measures. NAA (net assignable area) is an institutional programming measure, and it excludes general circulation and mechanical rooms. Equal insets communicate a general order rather than numeric proportions or a formula. The note beneath the ladder warns that BOMA and FICM draw boundaries differently and must not be combined without confirming compatible definitions. GBA (gross building area)outside face of exterior wallsall areasRentableUsable + primary circulation + serviceexcludes vertical penetrationsUsableNAA + secondary circulationexcludes shared coreNAA (net assignable area)excludes general circulation and mechanical roomsLargestCompatible study model: GBA ⊃ Rentable ⊃ Usable ⊃ NAAANSI/BOMA Z65.1 (office-leasing standard) sets Rentable and Usable · FICM (institutional programming standard) sets NAA — different boundariesSmallest

Conceptual study model only — NAA is measured inside the walls enclosing each assignable space, and BOMA and FICM measures must not be combined in one calculation without confirming compatible definitions.

Confusions / comparison

Area typeMeasured toIncludesExcludes
GBAOutside face of exterior wallsAll areas — occupied, circulation, mechanical, vertical penetrationsNothing (most inclusive)
UsableInside face of exterior walls; finish face of walls enclosing vertical penetrationsNet area + secondary circulationShared building core (tenant-shared service areas)
Rentable(Derived from Usable)Usable area + service areas + primary circulationVertical penetrations (stairs, elevators, shafts)
NAAPer the institutional programming standard in useProgrammatic / assigned spaceIn BRM’s model: general circulation and mechanical rooms; confirm other exclusions by standard

→ prog-efficiency-net-to-gross (this module): how the three efficiency factors use these four area types · prog-adjacency-diagrams (this module): the diagramming tools used once NAA is established · prog-criteria-to-block-diagram (this module): how the program’s NAA requirements are sized and arranged.

Spotted an issue with this card? Tell us →

Related units