Sheet A-104
Enclosureconcept
Window and door performance and frame details
One-line orientation
Window performance has three separate measures: U-factor for heat conduction, SHGC for solar heat gain, and air leakage for drafts. Do not treat them as the same thing.
Key points
- High-performance window — three factors, three heat paths:
- U-value / R-value → conduction: how readily heat conducts through the assembly (lower U-value = better insulator).
- Low-e glazing: generally reduces heat transfer and solar heat gain.
- Air leakage → infiltration: air moving through the assembly, measured in CFM.
- Key metrics to know: U-value, Visible Light Transmission (VLT), and SHGC. VLT is the daylight/views metric (visible light only), distinct from SHGC (total solar energy).
- Frame material: vinyl has the most thermal expansion; detail the frame so movement and thermal bridging do not undermine the assembly.
- Door frames — anchoring into the wall:
- To masonry: anchor tabs that sit between the courses.
- To steel-stud framing: dedicated stud connection.
- To wood-stud framing: dedicated stud connection.
- The frame must be positively tied to the surrounding structure for each substrate type.
Confusions / comparison
| Window metric | What it measures | Heat path | ”Better” direction |
|---|---|---|---|
| U-factor (U-value) | Conductive heat transfer through the assembly | Conduction | Lower = better insulation |
| SHGC | Solar heat admitted through the window | Solar gain | Lower in hot climates; higher can aid passive solar in cold |
| Air leakage | Air infiltration through the unit | Infiltration (CFM) | Lower CFM = tighter |
| VLT | Visible light transmitted | (daylighting) | Depends on daylight/glare goals |
Hollow-metal door frame — anchoring by substrate:
| Wall type | Anchor method |
|---|---|
| Masonry | Anchor tabs that sit between the courses |
| Steel-stud | Dedicated stud connection |
| Wood-stud | Dedicated stud connection |
Related
→ The four enclosure control layers (this topic): openings are where control layers must stay continuous · Vapor retarders: perm classes and placement (this topic): condensation control at glazing · Glass glazing types (Construction): annealed/tempered/laminated/insulated glazing that fills the frame.